Friday, 19 August 2016

Sharp MX2000 – Sharp MX2700 Copier - How to upgrade the software – error list

DIGITAL FULL COLOR MULTIFUNCTIONAL SYSTEM – Sharp MX- 2300/2700 G - MX-2300/2700 N 
Firmware upgrade procedure
Purpose : Version-up
Function (Purpose) : Used to execute the firmware update.
Section : —
Item : Adjustment
Operation/Procedure
NOTE: To update the firmware, set DIP SW 2 on the MFP control PWB to ON.
1) Insert the USB memory into the machine.
* When USB is not connected, "INSERT A STORAGE FIRMWARE STORED ON" is displayed. When [OK] button is pressed, the display is shifted to the folder or file selection screen.
2) When a firmware update folder or file button is pressed, the display is shifted to the firmware update screen.
* The number of buttons depends on the number of files in the inserted USB memory.
A folder name or file name is displayed on the button.
If the folder name or file name is of more than 34 characters, only 34 characters are displayed.
For a folder name, "<DIR>" is displayed at the head.
* When [ .. ] button is pressed on the file selection screen, the display is shifted to the folder or file selection screen. On the folder or file selection screen, the keys are disabled.
* The path of the folder or file is displayed on the title section.
If the path is of more than 50 characters, only 50 characters are displayed.
3) The current version and the update version are displayed for each firmware.
4) When a button of the firmware to be updated is selected, it is highlighted.
* When the selected button is pressed again, its selection is canceled (normal display).
* When [ALL] button is pressed, all the buttons are selected and highlighted.
* If there is a page over [^], an active display is shown and the page moves up. If there is no page upward, the display grays out and the operation is invalid.
When there is a page under [v], the display becomes active and the page is shifted down. When there is no page under [v], the display grays out and the operation is invalid.
5) Press [EXECUTE] button.  [EXECUTE] button is highlighted, and [YES] and [NO] buttons are changed from gray-out display to active display.
* If no firmware button is selected, [EXECUTE] button is disabled.
6) Press [YES] button.
[YES] button is highlighted, and update of the selected firmware is executed.
* When [NO] and [EXECUTE] button are pressed, the display returns to the firmware select screen. At that time, the selected firmware remains highlighted, and [EXECUTE] button returns to the normal display.
7) After completion of update, the result is displayed.
When the operation is completed normally, "COMPLET" is displayed. In case of an error, "ERROR" and the firmware where the error occurred are displayed.
* The operation cannot be interrupted midway.
* When [OK] button is pressed, the machine is rebooted.
* When [CA] key is pressed on the folder or file selection screen or the file selection screen, the simulation is terminated.
* When [SYSTEM SETTINGS] key is pressed on the folder or file selection screen or the file selection screen, the display returns to the sub code entry screen.
* When [CA] key or [SYSTEM SETTINGS] key is pressed to exit the simulation on the file version display screen and the following screens before execution, the machine is rebooted.
Error code list and Update target data
Click on the charts to magnify