Be
careful to follow the disassembly sequence described here.Otherwise,
the product may be damaged.
Be sure to carefully read and understand the safety instructions before
performing any work as the IC chips on the PCB are vulnerable to static
electricity.
In order to assemble reverse the order of disassembly.
Main Disassembly
1. Power on and Open the
Deck, Separate CD-Door.
2. Unfasten 4 screws on
the 2 side Cover. : BH 3*10 BLACK
(Be careful not to make any scratches as you remove
them.)
4. Separate the Front
panel
5. Unfasten 5 Screws in
SMPS and detach AC-CORD & 15P shield wire. : BH 3*10 WHITE
6. Unfasten 2 screws up
the DECK, Separate DECK from MECHA. : BH 3*10 BLACK
7. Unfasten 2 screws and
detach DECK wire. : BH 3*10 WHITE
8. Unfasten 10 screws,
and then separate the front PCB from Front Panel. : BH 3*10 WHITE
DECK Disassembly
1. Separate Tray - Disc
from DECK.
2.
Lift up Holder-Cable, separate Traverse-DECK.
3.
Disassemble complete.
Cases of the SMPS Protection.
1)
If there is over current at the AMP IC. (Speaker Wire Short)
2) If temperature of the AMP IC is over 150 ℃.
3) There is no power supply for amp.
How to check AMP in
Power Protection
CAUTION
Do not connect the power cord during
the test.
MICOM, MPEG Initialization & Update.
MICOM Reset.
During STANDBY mode, push the ‘STOP” Button 5 Seconds. If VFD blinking, reset
is finished.
Micom Update (Only for Flash Micom)
(Method 1) MAIN PCB UTCN1 for
update JIG. To update MICOM, it need Computer, Rom Writer, USB Cables.
(Method 2) Insert USB Memory, and play. “Update” will be displayed. Set will
be power off when finish.
(Method 3) Insert Update DISC, and play. “Update” will be displayed. Set will
be power off when finish.
Micom & MPEG Version Check
1) Power On.
2) CD open status.
3) Push the number NEXT for 5
seconds, check the MICOM version.
4) Push the number PREVIOUS for
5 seconds, check the MPEG version.
MPEG Update
1) Insert USB Memory or Update DISC which have Update file, and play.
“Update” will be displayed.
2) When finish the Set will be power off → on automatically.
3) And then the Deck is automatically open.
MPEG Reset
1) During “No Disc” Displayed, push the stop Button 5 seconds. After
displayed “INITIALIZE” set will power off
automatically.
Region code setting.
The inserting method of Region Code after replacing the Main PBA.
When replacing the Main
PBA and System Micom should be inserted the region code.
The set is not working properly if you don't insert the region code.
The region code is inserted by the remote control.
During “AUX” status.
MX-F730/F730CB : Push the “ENTER” button 10 Second.
MX-F730D : Push the “D” button (blue key) 10 Second.
2) When displayed ‘TEST”,
import 46 to set the buyer.
3) When displayed ‘– – –’,
import the buyer code.
The buyer setting code can find in the table named “MX-F7**_Option_Table”.
4) It will show the buyer
that you set up. Then the buyer setting is succeed.
Region codes.
SMPS
schematic.
Amp
schematic.
No comments:
Post a Comment